Shop

  • V-Form Coalescer / Pre-Filter Generic name for page copy & search — model above is title / SKU Compact V-form synthetic coalescer / pre-filter (EN 779 G4 / ISO Coarse) for gas-turbine air-intake systems. V-form synthetic pack with a reverse-flow option (MVX-G) packing high media area into a short depth for gas-turbine coalescing and pre-filtration. Key Benefits
    • Compact V-form
    • Reverse-flow option
    • High media area
    • Low resistance
  • High-Temperature V-Bank Fine Filter (120 °C) Generic name for page copy & search — model above is title / SKU Plastic V-bank fine filter (EN 779 F7–F9 / ISO ePM1) rated to 120 °C for warm-air HVAC and process duty. Polyamide-framed V-bank fine filter rated to 120 °C for elevated-temperature ventilation while retaining low resistance. Key Benefits
    • 120 °C rated
    • High airflow
    • Low pressure drop
    • High media area
  • High-Temperature V-Bank Filter (350 °C) Generic name for page copy & search — model above is title / SKU Silicone-free microglass V-bank filter (EN 779 M6–F8 / ISO ePM1) rated to 350 °C for painting / curing ovens. High-capacity microglass V-bank with metal separators and an extruded aluminium / steel frame, rated to 350 °C and silicone-free. Key Benefits
    • 350 °C rated
    • Silicone-free
    • High surface area
    • Energy saver
  • Energy-Efficient V-Bank Fine Filter Generic name for page copy & search — model above is title / SKU Energy-efficient mini-pleat V-bank fine filter (EN 779 F7–F9 / ISO ePM1) balancing efficiency and fan energy. MVEE offers a strong efficiency-to-energy balance for everyday HVAC final filtration. Key Benefits
    • Energy efficient
    • High media area
    • Stable efficiency
    • Incinerable
  • HEPA / ULPA Box Filter (Plastic Frame) Generic name for page copy & search — model above is title / SKU Plastic / metal-framed V-pleat box HEPA / ULPA filter (E10–U15) for high-airflow cleanroom stages. 592×592×292 box with plastic or metal frame for high airflow at low resistance where a lightweight frame is preferred. Key Benefits
    • Lightweight frame option
    • High airflow
    • Individually EN 1822 tested
    • 292 mm
  • High-Temperature HEPA Box Filter (250 °C) Generic name for page copy & search — model above is title / SKU Microglass box filter spanning F7 fine up to H14 HEPA (EN 1822), rated to 250 °C for high-temperature clean air. High-temperature box with microglass separators and stainless / galvanised frame, silicone-sealed and rated to 250 °C — fine to absolute in one range. Key Benefits
    • 250 °C rated
    • Fine to HEPA H14
    • Robust metal construction
    • Silicone-sealed
  • V-Bank Fine Filter (A+ Energy) Generic name for page copy & search — model above is title / SKU Energy-optimised mini-pleat V-bank fine filter reaching Eurovent A+ (EN 779 F7–F9 / ISO ePM1). MVX maximises media area and minimises resistance for Eurovent A+ energy performance in HVAC and gas-turbine final filtration. Key Benefits
    • Eurovent A+ energy
    • Lowest pressure drop
    • High media area
    • Long life
  • W-Bank Fine Filter (Economical) Generic name for page copy & search — model above is title / SKU Economical W-bank mini-pleat fine filter (EN 779 M6–F8 / ISO ePM10–ePM1) for value-driven HVAC filtration. MW uses a W-form pack for good media area at an economical price point for general HVAC. Key Benefits
    • Economical
    • Good media area
    • Low resistance
    • Incinerable
  • Down Flow Weighing / Dispensing Booth Generic name for page copy & search — model above is title / SKU Turnkey down-flow weighing booth (Class 100 / ISO 5 / GMP A) in AISI 304/316 with multi-stage filtration up to H14/U15, PLC automation and 0.45 m/s laminar down-flow per EU GMP Annex 1. NTK booths protect raw materials during weighing and mixing with laminar down-flow at 0.45 m/s ±20%. Multi-stage filtration (G4/M5 → F7–F9 → E10–H13 → H14/U15 main and exhaust), neutral / negative / positive pressurisation modes, and full PLC monitoring. Delivered turnkey with design, commissioning, DOP tests and validation; ATEX-certificated and BIBO options available. Key Benefits
    • Class 100 / ISO 5 / GMP A
    • PLC control & alarm system
    • AISI 304/316 construction
    • Turnkey with validation & DOP tests
  • Photoelectric smoke detector designed for installation in HVAC ducts to detect smoke and prevent its circulation.
    Category Specification
    Type Photoelectric, 24V DC
    Sensitivity 0.5–4% obs/m
    Compatible Duct Velocity 0.3–1.5 m/s
    Output Alarm relay (2A)
    Features Sampling tube, test port
    Temperature Range -20 to 60°C
    Certifications UL 268A, CE
    Mounting Duct-mounted
  • Sturdy return air grille with an integrated filter frame for easy maintenance and improved indoor air quality.
    Category Specification
    Material Steel / Aluminum, powder‑coated
    Available Sizes Standard 300×300 mm to 600×600 mm
    Filter Type 25 mm thick G4 / F5 filter
    Mounting Ceiling or wall installation
    Features Removable grille, adjustable louvers
    Airflow Capacity Up to 1000 m³/h
    Finish White RAL 9010
  • Variable Air Volume (VAV) terminal unit for precise temperature control and energy efficiency in zoned HVAC systems.
    Category Specification
    Product Single Duct VAV Terminal Unit
    Description Variable Air Volume (VAV) terminal unit for precise temperature control and energy efficiency in zoned HVAC systems.
    Applications Commercial offices, hotels, educational institutions
    Air Distribution Type Single Duct VAV
    Function Modulates airflow to maintain zone temperature and reduce energy consumption
    Control Compatible with BMS, thermostats, and pressure-independent controls
    Construction Insulated casing with low‑leakage damper
    Airflow Range Varies by model (typically 200–2000 m³/h)
    Pressure Drop Low-pressure design for energy efficiency
    Power 24V actuator (optional EC motorized damper)
    Mounting Ceiling or duct-mounted
    Features Quiet operation, precise airflow control, optional reheat coil
Go to Top