- Individually EN 1822 tested
- 55 mm frame
- Low pressure drop
- Test certificate supplied
-
Mini-Pleat HEPA / ULPA Panel (55 mm) Generic name for page copy & search — model above is title / SKU 55 mm mini-pleat HEPA / ULPA panel, individually EN 1822-tested from E10 to U15. 55 mm aluminium-framed mini-pleat absolute panel for cleanroom terminal and duct filtration. Key Benefits
-
Mini-Pleat HEPA / ULPA Panel (66–150 mm) Generic name for page copy & search — model above is title / SKU Deep 66–150 mm mini-pleat HEPA / ULPA panel, individually EN 1822-tested E10–U15, in aluminium or MDF frame. Deeper mini-pleat absolute panel (66 / 70 / 78 / 150 mm) for higher-airflow cleanroom terminals and laminar-flow units; aluminium or MDF frame. Key Benefits
- Individually EN 1822 tested
- 66–150 mm depths
- Aluminium or MDF frame
- Low pressure drop
-
Gel-Seal HEPA / ULPA Panel (73 / 80 mm) Generic name for page copy & search — model above is title / SKU Gel-seal HEPA / ULPA panel (73 / 80 mm) that seals into a knife-edge grid for leak-free cleanroom ceilings. Fluid-gel channel mates with a knife-edge grid for a leak-free seal without gasket bypass — for pharmaceutical and aseptic ceilings. Key Benefits
- Leak-free gel seal
- No gasket bypass
- Individually EN 1822 tested
- 73 / 80 mm
-
Application Pharmaceutical & aseptic ceilings; High-airflow cleanrooms Classification (EN 1822) E10 – U15 Filter Frame Aluminium / MDF with fluid gel Media Microglass Fibre Max. Operating Temperature (°C) up to 80 °C Max. Final Pressure Drop 600 Pa Max. Airflow 1.25 × nominal flow (size dependent) Dimension Standard Standard modular front sizes — EN 15805 (e.g. 287 / 490 / 592 / 610 mm) Installation Options Front- and side-access housings and holding frames available Depth 88 / 104 mm 
-
HEPA / ULPA Box Filter (292 mm) Generic name for page copy & search — model above is title / SKU Deep V-pleat box HEPA / ULPA filter (292 mm), individually EN 1822-tested E10–U15, for cleanroom AHUs. 292 mm V-pleat microglass box in MDF / metal frame for high airflow at low resistance in cleanroom air-handling units. Key Benefits
- High airflow, low ΔP
- Deep V-pleat pack
- Individually EN 1822 tested
- 292 mm
-
HEPA / ULPA Box Filter (292 mm, Metal) Generic name for page copy & search — model above is title / SKU Metal-framed deep V-pleat box HEPA / ULPA filter (292 mm), EN 1822-tested E10–U15. 292 mm box variant with sheet-metal frame for robust high-volume absolute filtration in cleanroom AHUs. Key Benefits
- Robust metal frame
- High airflow
- Individually EN 1822 tested
- 292 mm
-
HEPA / ULPA Box Filter (Plastic Frame) Generic name for page copy & search — model above is title / SKU Plastic / metal-framed V-pleat box HEPA / ULPA filter (E10–U15) for high-airflow cleanroom stages. 592×592×292 box with plastic or metal frame for high airflow at low resistance where a lightweight frame is preferred. Key Benefits
- Lightweight frame option
- High airflow
- Individually EN 1822 tested
- 292 mm
-
HEPA Terminal Ceiling Module (Micro Hood) Generic name for page copy & search — model above is title / SKU HEPA / ULPA terminal ceiling module (E10–U15) with integral duct collar and adjustable airflow for cleanroom ceilings. Combines a mini-pleat HEPA / ULPA filter with a 150–400 mm duct collar and adjustable airflow for direct cleanroom ceiling and laminar-cabin installation. Key Benefits
- Integral duct collar
- Adjustable airflow option
- Individually EN 1822 tested
-
Mini-Pleat HEPA / ULPA Panel (110 / 150 mm) Generic name for page copy & search — model above is title / SKU Deep 110/150 mm mini-pleat HEPA / ULPA panel, individually EN 1822-tested E10–U15, in aluminium or MDF frame for higher-airflow absolute filtration. Deeper HFS mini-pleat absolute panel (110 or 150 mm) with microglass media and hotmelt separators, for cleanroom terminals and duct stages that need more media area and airflow than slim panels. Key Benefits
- Individually EN 1822 tested
- 110 / 150 mm depths
- Aluminium or MDF frame
- Higher airflow per panel
-
Mini-Pleat HEPA / ULPA Panel (90 / 150 mm) Generic name for page copy & search — model above is title / SKU HFP mini-pleat HEPA / ULPA panel in 90 or 150 mm aluminium profile, individually EN 1822-tested E10–U15 (gasket-seal version of the HFP gel-seal range). Aluminium-profile HFP absolute panel in 90 or 150 mm depth with gasket sealing, individually tested to EN 1822 — the conventional-seal alternative to the HFP gel-seal series for cleanroom ceilings and housings. Key Benefits
- Individually EN 1822 tested
- 90 / 150 mm depths
- Gasket-seal aluminium profile
-
ATEX Pleated Panel Pre-Filter Generic name for page copy & search — model above is title / SKU ATEX 2014/34/EU pleated panel pre-filter (EN 779 G4 / ISO Coarse) for explosive zones 1, 2, 21 and 22, marked II 2 G Ex h IIC Gb, with integrated earthing lugs. Ex-proof pleated panel pre-filter with synthetic media and galvanised, stainless or aluminium frame, compliant with ATEX Directive 2014/34/EU for gas and dust zones 1, 2, 21 and 22. Supplied with integrated earthing cable lugs. Key Benefits
- ATEX 2014/34/EU compliant
- Zones 1, 2, 21, 22
- Integrated earthing lugs
- Light, rigid, low ΔP
-
ATEX Pocket / Bag Filter (M5–F8) Generic name for page copy & search — model above is title / SKU ATEX 2014/34/EU glass-fibre pocket filter (EN 779 M5–F8 / ISO ePM10–ePM1) for explosive zones 1, 2, 21 and 22, with earthing lugs and colour-coded media. Ex-proof glass-fibre pocket / bag filter with galvanised frame and sewn fibre assembly, colour-coded by grade (M5 white, M6 green, F7 pink, F8 yellow). ATEX 2014/34/EU compliant for zones 1, 2, 21, 22; supplied with earthing lugs. Key Benefits
- ATEX 2014/34/EU compliant
- Low initial pressure drop
- Low energy use
- Colour-coded media