- Washable & reusable
- Rigid & robust
- High-temperature capable
- Low initial pressure drop
-
Washable Metal Mesh Pre-Filter Generic name for page copy & search — model above is title / SKU Cleanable aluminium / stainless knitted wire-mesh pre-filter rated to 200 °C for spark arrest, fume aspiration and gas-turbine intakes. Durable washable knitted wire-mesh in aluminium or stainless steel, rated to 200 °C. Where used in spark / explosive-atmosphere duty, confirm the exact ATEX marking with the manufacturer. Key Benefits
-
High-Temperature Panel Filter (270 °C) Generic name for page copy & search — model above is title / SKU Silicone-free microglass panel filter (EN 779 M5–F8 / ISO ePM10–ePM1) rated to 270 °C for heat-treatment pre-filtration. Depth-loading microglass panel with galvanised / stainless frame and a silicone-free high-temperature gasket, rated to 270 °C. Key Benefits
- 270 °C rated
- Silicone-free
- Depth loading
- Robust metal frame
-
Rigid-Frame Pleated Pre-Filter Generic name for page copy & search — model above is title / SKU Light rigid pleated pre-filter (EN 779 G4 / ISO Coarse) with ABS, galvanised or stainless frame and a leakage-free polyurethane seal. Rigid-frame pleated panel with polyurethane sealant for a leak-free seal; ABS, galvanised or stainless frame options for HVAC and industrial primary filtration. Key Benefits
- Light & rigid
- Leakage-free seal
- Tidy pleat spacing
- Frame options
-
Water-Repellent Rigid Pleated Pre-Filter Generic name for page copy & search — model above is title / SKU Water-repellent rigid pleated pre-filter (EN 779 G4 / ISO Coarse) for high-humidity, coastal and gas-turbine intake conditions. MSKPN with water-repellent media that maintains dust-holding in high-humidity and gas-turbine intake air where standard media would wet out. Key Benefits
- Water-repellent media
- Rigid frame
- Leak-free seal
- Stable in humid air
-
Advanced indoor air quality sensor monitoring CO2, VOCs, temperature, and humidity for optimal environmental control.
Category Specification Parameters Measured CO₂ (0–5000 ppm), VOCs (index), Temperature (0–50°C), Humidity (0–100% RH) Accuracy CO₂ ±50 ppm, Temperature ±0.5°C, Humidity ±3% RH Output Options Analog (0–10V / 4–20mA), Digital (Modbus, BACnet) Power Supply 12–24V DC Response Time <60 seconds Mounting Type Wall or duct mounting Certifications CE, RoHS -
Mini-Pleat V-Bank Fine Filter Generic name for page copy & search — model above is title / SKU Mini-pleat V-bank fine filter (EN 779 M6–F9 / ISO ePM10–ePM1) delivering high airflow at low resistance. V-bank header-frame filter folding a large microglass area into a compact cell for high airflow, low pressure drop and strong energy performance. Key Benefits
- High airflow, low resistance
- Very high media area
- Energy saver
- Incinerable
-
Terminal Single-Cell V Filter Generic name for page copy & search — model above is title / SKU Slim single-cell V terminal filter (F8 up to H13) for terminal filtration in air-treatment units. Compact single-cell V spanning F8–F9 fine to E11–H13 absolute in one slim footprint, for terminal housings and air-treatment units. Key Benefits
- High airflow
- Low pressure drop
- Compact single-cell
- Wide class range
-
Activated-Carbon V-Cell Filter Generic name for page copy & search — model above is title / SKU Deep V-cell granular-activated-carbon filter holding 12–20 kg carbon for extended gas / odour adsorption. V-cell configuration maximising carbon mass (12–20 kg) for long-life gas and odour adsorption in HVAC and exhaust. Key Benefits
- High carbon charge
- Long life
- V-cell high capacity
- Refillable
-
Activated-Carbon Combination V-Bank Generic name for page copy & search — model above is title / SKU Combination V-bank carrying activated carbon between synthetic layers for simultaneous gas / odour and particulate control at high airflow. Activated carbon between synthetic media in a V-bank for one-stage molecular + particulate capture in HVAC, museums and airports. Key Benefits
- Gas + particulate in one stage
- High airflow
- Low resistance
- High carbon area
-
Acid-Gas Activated-Carbon V-Bank Generic name for page copy & search — model above is title / SKU Impregnated-carbon combination V-bank targeting SO₂, acids, ammonia and VOCs alongside particulate. MV-ACX uses impregnated activated carbon to target acidic gases (SO₂), ammonia and VOCs in one high-airflow V-bank stage. Key Benefits
- Targets SO₂, acids, NH₃, VOC
- High airflow
- Low resistance
- Combination filtration
-
ATEX Mini-Pleat V-Bank Filter (M6–F9) Generic name for page copy & search — model above is title / SKU ATEX 2014/34/EU mini-pleat V-bank filter (EN 779 M6–F9 / ISO ePM10–ePM1) for explosive zones 1, 2, 21 and 22 — compact, energy-saving and VDI 6022 compliant. Ex-proof mini-pleat V-bank filter with microglass media and hotmelt separators, ATEX 2014/34/EU compliant for zones 1, 2, 21, 22. Compact, high-surface-area design; the MV line fully meets VDI 6022 hygiene requirements. Key Benefits
- ATEX 2014/34/EU compliant
- Compact, high surface area
- Energy saver
- VDI 6022 compliant
-
Carbon + F7 Combination V-Bank Generic name for page copy & search — model above is title / SKU Combination V-bank delivering ISO ePM1 (F7) particulate efficiency plus activated-carbon gas / odour removal in a single filter. Combines an F7 microglass particulate stage with an activated-carbon layer for simultaneous PM1 and gas / odour control. Key Benefits
- F7 particulate + carbon
- One-stage solution
- High airflow
- Space-saving