- Nanofiber high efficiency
- Low energy use
- Up to 100% RH
- Euro vent energy-rated
-
Nanofibre Pocket Fine Filter Generic name for page copy & search — model above is title / SKU Nanofibre-enhanced synthetic pocket fine filter reaching F9 / ISO ePM1 85% at reduced energy, up to 100% RH. Adds a nanofibre layer to the synthetic pocket filter for higher ePM1 efficiency at low energy, tolerant to 100% relative humidity. Key Benefits
-
Metal-Frame Pleated Pre-Filter Generic name for page copy & search — model above is title / SKU Pleated panel pre-filter (EN 779 G4 / ISO Coarse) in galvanised or stainless-steel frame for robust HVAC and industrial duty. Metal-framed pleated synthetic panel with low resistance and high dust-holding, suited to robust HVAC and industrial primary filtration. Key Benefits
- Robust metal frame
- Low pressure drop
- High dust-holding
- Custom sizes
-
Washable Metal Mesh Pre-Filter Generic name for page copy & search — model above is title / SKU Cleanable aluminium / stainless knitted wire-mesh pre-filter rated to 200 °C for spark arrest, fume aspiration and gas-turbine intakes. Durable washable knitted wire-mesh in aluminium or stainless steel, rated to 200 °C. Where used in spark / explosive-atmosphere duty, confirm the exact ATEX marking with the manufacturer. Key Benefits
- Washable & reusable
- Rigid & robust
- High-temperature capable
- Low initial pressure drop
-
Rigid-Frame Pleated Pre-Filter Generic name for page copy & search — model above is title / SKU Light rigid pleated pre-filter (EN 779 G4 / ISO Coarse) with ABS, galvanised or stainless frame and a leakage-free polyurethane seal. Rigid-frame pleated panel with polyurethane sealant for a leak-free seal; ABS, galvanised or stainless frame options for HVAC and industrial primary filtration. Key Benefits
- Light & rigid
- Leakage-free seal
- Tidy pleat spacing
- Frame options
-
Water-Repellent Rigid Pleated Pre-Filter Generic name for page copy & search — model above is title / SKU Water-repellent rigid pleated pre-filter (EN 779 G4 / ISO Coarse) for high-humidity, coastal and gas-turbine intake conditions. MSKPN with water-repellent media that maintains dust-holding in high-humidity and gas-turbine intake air where standard media would wet out. Key Benefits
- Water-repellent media
- Rigid frame
- Leak-free seal
- Stable in humid air
-
Advanced indoor air quality sensor monitoring CO2, VOCs, temperature, and humidity for optimal environmental control.
Category Specification Parameters Measured CO₂ (0–5000 ppm), VOCs (index), Temperature (0–50°C), Humidity (0–100% RH) Accuracy CO₂ ±50 ppm, Temperature ±0.5°C, Humidity ±3% RH Output Options Analog (0–10V / 4–20mA), Digital (Modbus, BACnet) Power Supply 12–24V DC Response Time <60 seconds Mounting Type Wall or duct mounting Certifications CE, RoHS -
Mini-Pleat V-Bank Fine Filter Generic name for page copy & search — model above is title / SKU Mini-pleat V-bank fine filter (EN 779 M6–F9 / ISO ePM10–ePM1) delivering high airflow at low resistance. V-bank header-frame filter folding a large microglass area into a compact cell for high airflow, low pressure drop and strong energy performance. Key Benefits
- High airflow, low resistance
- Very high media area
- Energy saver
- Incinerable
-
Terminal Single-Cell V Filter Generic name for page copy & search — model above is title / SKU Slim single-cell V terminal filter (F8 up to H13) for terminal filtration in air-treatment units. Compact single-cell V spanning F8–F9 fine to E11–H13 absolute in one slim footprint, for terminal housings and air-treatment units. Key Benefits
- High airflow
- Low pressure drop
- Compact single-cell
- Wide class range
-
V-Form Coalescer / Pre-Filter Generic name for page copy & search — model above is title / SKU Compact V-form synthetic coalescer / pre-filter (EN 779 G4 / ISO Coarse) for gas-turbine air-intake systems. V-form synthetic pack with a reverse-flow option (MVX-G) packing high media area into a short depth for gas-turbine coalescing and pre-filtration. Key Benefits
- Compact V-form
- Reverse-flow option
- High media area
- Low resistance
-
High-Temperature V-Bank Fine Filter (120 °C) Generic name for page copy & search — model above is title / SKU Plastic V-bank fine filter (EN 779 F7–F9 / ISO ePM1) rated to 120 °C for warm-air HVAC and process duty. Polyamide-framed V-bank fine filter rated to 120 °C for elevated-temperature ventilation while retaining low resistance. Key Benefits
- 120 °C rated
- High airflow
- Low pressure drop
- High media area
-
Energy-Efficient V-Bank Fine Filter Generic name for page copy & search — model above is title / SKU Energy-efficient mini-pleat V-bank fine filter (EN 779 F7–F9 / ISO ePM1) balancing efficiency and fan energy. MVEE offers a strong efficiency-to-energy balance for everyday HVAC final filtration. Key Benefits
- Energy efficient
- High media area
- Stable efficiency
- Incinerable
-
V-Bank Fine Filter (A+ Energy) Generic name for page copy & search — model above is title / SKU Energy-optimised mini-pleat V-bank fine filter reaching Eurovent A+ (EN 779 F7–F9 / ISO ePM1). MVX maximises media area and minimises resistance for Eurovent A+ energy performance in HVAC and gas-turbine final filtration. Key Benefits
- Eurovent A+ energy
- Lowest pressure drop
- High media area
- Long life
-
W-Bank Fine Filter (Economical) Generic name for page copy & search — model above is title / SKU Economical W-bank mini-pleat fine filter (EN 779 M6–F8 / ISO ePM10–ePM1) for value-driven HVAC filtration. MW uses a W-form pack for good media area at an economical price point for general HVAC. Key Benefits
- Economical
- Good media area
- Low resistance
- Incinerable
-
Photoelectric smoke detector designed for installation in HVAC ducts to detect smoke and prevent its circulation.
Category Specification Type Photoelectric, 24V DC Sensitivity 0.5–4% obs/m Compatible Duct Velocity 0.3–1.5 m/s Output Alarm relay (2A) Features Sampling tube, test port Temperature Range -20 to 60°C Certifications UL 268A, CE Mounting Duct-mounted -
Sturdy return air grille with an integrated filter frame for easy maintenance and improved indoor air quality.
Category Specification Material Steel / Aluminum, powder‑coated Available Sizes Standard 300×300 mm to 600×600 mm Filter Type 25 mm thick G4 / F5 filter Mounting Ceiling or wall installation Features Removable grille, adjustable louvers Airflow Capacity Up to 1000 m³/h Finish White RAL 9010 -
Variable Air Volume (VAV) terminal unit for precise temperature control and energy efficiency in zoned HVAC systems.
Category Specification Product Single Duct VAV Terminal Unit Description Variable Air Volume (VAV) terminal unit for precise temperature control and energy efficiency in zoned HVAC systems. Applications Commercial offices, hotels, educational institutions Air Distribution Type Single Duct VAV Function Modulates airflow to maintain zone temperature and reduce energy consumption Control Compatible with BMS, thermostats, and pressure-independent controls Construction Insulated casing with low‑leakage damper Airflow Range Varies by model (typically 200–2000 m³/h) Pressure Drop Low-pressure design for energy efficiency Power 24V actuator (optional EC motorized damper) Mounting Ceiling or duct-mounted Features Quiet operation, precise airflow control, optional reheat coil -
Four-way square ceiling diffuser designed for efficient air distribution and aesthetic integration into suspended ceilings.
Category Specification Media Granular activated carbon or impregnated non-woven Filter Class Typically G4 + carbon layer Adsorption Capability VOCs, odors, gases (e.g., SO₂, NO₂) Initial Pressure Drop 50–150 Pa Frame Galvanized steel or aluminum Temperature Limit Max 40–60°C Available Sizes Standard panels (e.g., 595×595×46 mm / 595×595×96 mm) Application Airflow 500–2500 m³/h depending on size -
Ultra-low penetration air (ULPA) filter for the most demanding cleanroom applications, capturing 99.9995% of particles at 0.12 microns.
Category Specification Efficiency 99.9995% @ 0.12 μm (EN 1822) Media Glass fiber Frame Material Anodized aluminum Available Sizes 610 × 610 × 69 mm / 610 × 610 × 150 mm Initial Pressure Drop 250–450 Pa Air Flow Capacity 500–1500 m³/h Temperature Limit 70°C Cleanroom Class Compatibility ISO Class 1–3