| Category | Specification |
|---|---|
| Media | Granular activated carbon or impregnated non-woven |
| Filter Class | Typically G4 + carbon layer |
| Adsorption Capability | VOCs, odors, gases (e.g., SO₂, NO₂) |
| Initial Pressure Drop | 50–150 Pa |
| Frame | Galvanized steel or aluminum |
| Temperature Limit | Max 40–60°C |
| Available Sizes | Standard panels (e.g., 595×595×46 mm / 595×595×96 mm) |
| Application Airflow | 500–2500 m³/h depending on size |
-
Odor control filter utilizing activated carbon media to absorb gaseous contaminants and VOCs.
-
Heating, Ventilation, and Air Conditioning (HVAC) systems are the backbone of healthy indoor environments. When equipped with the right filtration technology, they significantly improve Indoor Air Quality (IAQ) by removing airborne particles, harmful gases, chemical vapors, and unpleasant odors. High‑performance filters also reduce system load, lower energy consumption, and help decrease carbon emissions — making air purification both effective and sustainable. With Mikropor’s advanced HVAC filtration solutions, facilities can achieve cleaner, safer, and more efficient airflow. Each filter is engineered for maximum performance, ensuring reliable particle capture, optimized airflow resistance, and long service life. Whether for commercial buildings, industrial plants, healthcare facilities, or cleanroom environments, Mikropor filters support your sustainability goals while delivering superior air quality.
-
Mikropor coarse air filters serve as the first line of defense in HVAC and industrial ventilation systems. Engineered to capture large dust particles, fibers, lint, and debris, these filters protect downstream equipment and significantly extend the service life of fine, compact, and HEPA filtration stages. Ideal for commercial buildings, factories, warehouses, AHUs, FCUs, and general ventilation systems, Mikropor coarse filters deliver reliable performance with low pressure drop and high dust‑holding capacity — ensuring cleaner air and reduced maintenance costs.
MediaSynthetic
Final Pressure Drop250 Pa
Operating Temperature80°C
Filter Efficiency*G2 – G3 – G4
Filter Class**ISO Coarse * According to EN 779:2012 ** According to ISO 16890 
-
High-accuracy differential pressure transmitter for monitoring filter status and airflow in HVAC systems.
Category Specification Measurement Range 0–500 Pa (typical for filter monitoring) Accuracy ±1% FS Output Signal 4–20 mA, 0–10 V Power Supply 12–24 V DC Response Time <1 second Features Optional LCD display, IP65 housing Applications Filter status monitoring, airflow measurement -
Electronic air cleaner using electrostatic precipitation to remove fine particles, smoke, and oil mist.
Category Specification Efficiency 95%+ for 0.01–10 μm particles Ionization Voltage 5–12 kV Collector Cells Washable aluminum plates Airflow Capacity 1000–5000 m³/h per unit Pressure Drop 20–50 Pa Medium efficiency bag filter designed for HVAC systems requiring good dust holding capacity and low pressure drop.Category Specification Unit Size 600 × 600 × 300 mm Filter HEPA / ULPA (99.99% @ 0.3 μm) Airflow 500–900 m³/h Power Consumption 50–150 W Noise Level <55 dB(A) Material Aluminum frame Fan Type EC fan Cleanroom Efficiency ISO Class 5–7 Fan Filter Unit — Two-Stage (G4/M5 + HEPA) Generic name for page copy & search — model above is title / SKU Self-powered fan filter unit with two-stage filtration — G4/M5 pre-filter plus HEPA — delivering ISO 14644 laminar flow from 610×610, 610×915 or 610×1220 mm ceiling modules. Push-pull fan filter unit drawing room air through a G4 or M5 coarse pre-filter and discharging through a HEPA stage for the highest outlet purity. Aluminium-alloy / stainless 430 or 304 construction, 220 V 50 Hz, with normal and standby speed modes; standard or custom sizes. Key Benefits- Two-stage: G4/M5 + HEPA
- Laminar flow per ISO 14644 (≈0.45 m/s)
- Normal / standby speed modes
- Standard & custom sizes
Self-contained fan filter unit providing filtered air for cleanroom applications, typically with a HEPA or ULPA filter.Category Specification Unit Size 600 × 600 × 300 mm Filter HEPA / ULPA (99.99% @ 0.3 μm) Airflow 500–900 m³/h Power Consumption 50–150 W Noise Level <55 dB(A) Material Aluminum frame Fan Type EC fan Cleanroom Efficiency ISO Class 5–7 Compact Inertial Filter — Self-Cleaning Sand Separator Generic name for page copy & search — model above is title / SKU Compact, self-cleaning inertial sand separator in all-steel modular construction — up to 88–94% separation efficiency with no replaceable media, at roughly half the size of market-average inertial filters. The FC-INF-DF separates dust and sand by multiple-phase flow dynamics, bleeding the separated dust out through a small bleed fan (10–15% of air, by efficiency mode). All-steel, modular and maintenance-free for long-term service, with removable filtering panels for easy cleaning; mountable horizontally or vertically. Third-party lab-tested among the best inertial filters on the market. Key Benefits- Self-cleaning — no replaceable media
- Half the size of market average
- Efficiency up to A2 88% / A4 94%
- Removable panels, horizontal or vertical mounting
High-efficiency pleated pre-filter designed to capture large particles and extend the life of downstream filters.Category Specification Filter Class G4 (EN779:2012), ~90% arrestance Media Synthetic fiber / Polyester Frame Cardboard / Galvanized Steel / ABS Initial Pressure Drop 22–40 Pa Final Pressure Drop ≤200–250 Pa Air Flow 1180–3400 m³/h (varies by size, e.g., 595×595×22 mm at 1700 m³/h) Temperature Limit Max 80°C Common Sizes 595×595×20 / 46 / 96 mm (other sizes available) HEPA Terminal Housing (Ceiling Diffuser) Generic name for page copy & search — model above is title / SKU Ceiling terminal housing for HEPA panel filters, in standard (STC) or low-profile (LTC) top-collar and side-collar versions, with swirl, 4-direction or perforated diffusers and Ø150–250 mm collars. H-BOX terminal housings hold HEPA panels (305×305 up to 610×610 mm, depths 70–110 mm) in cleanroom ceilings. Variants: STC standard top collar, LTC low top collar (70/78 mm filters), plus side-collar versions; diffuser faces in swirl (DSW), 4-direction (D4D) or perforated (DP). Key Benefits- Standard & low-profile heights
- Top or side collar entry
- Swirl / 4-direction / perforated diffusers
- Fits 305–610 mm HEPA panels
Absolute HEPA filter providing high-level filtration for critical environments, capturing 99.95% of particles at 0.3 microns. Key Highlights:- Minipleat design
- lowest static pressure
Category Specification Applications Hospitals, pharmaceutical manufacturing, cleanrooms, laboratories Filter Type Panel Efficiency E10, E11, E12, H13, H14, U15, U16, U17 Media Type Microfine fiberglass Frame Material Anodised Aluminum Seal Type Neoprene Endless, PU Depth Available 69 mm, 70 mm, 80 mm Initial Pressure Drop 50 Pa Final Pressure Drop 600 Pa Operating Temperature & Humidity 80°C Standard Sizes 24×24×12, 24×12×12 Additional Details Individual certificate will be provided Certifications & Compliance EN1822 HEPA / ULPA Box Filter (292 mm) Generic name for page copy & search — model above is title / SKU Deep V-pleat box HEPA / ULPA filter (292 mm), individually EN 1822-tested E10–U15, for cleanroom AHUs. 292 mm V-pleat microglass box in MDF / metal frame for high airflow at low resistance in cleanroom air-handling units. Key Benefits- High airflow, low ΔP
- Deep V-pleat pack
- Individually EN 1822 tested
- 292 mm
Mini-Pleat HEPA / ULPA Panel (47 mm) Generic name for page copy & search — model above is title / SKU Slim 47 mm mini-pleat HEPA / ULPA panel, individually EN 1822-tested from E10 to U15, in extruded anodised aluminium. 47 mm aluminium-framed mini-pleat absolute panel with microglass media and hotmelt separators, for slim cleanroom terminals and duct stages. Key Benefits- Individually EN 1822 tested
- Slim 47 mm frame
- Low pressure drop
- Test certificate supplied
Mini-Pleat HEPA / ULPA Panel (66–150 mm) Generic name for page copy & search — model above is title / SKU Deep 66–150 mm mini-pleat HEPA / ULPA panel, individually EN 1822-tested E10–U15, in aluminium or MDF frame. Deeper mini-pleat absolute panel (66 / 70 / 78 / 150 mm) for higher-airflow cleanroom terminals and laminar-flow units; aluminium or MDF frame. Key Benefits- Individually EN 1822 tested
- 66–150 mm depths
- Aluminium or MDF frame
- Low pressure drop
Gel-Seal HEPA / ULPA Panel (73 / 80 mm) Generic name for page copy & search — model above is title / SKU Gel-seal HEPA / ULPA panel (73 / 80 mm) that seals into a knife-edge grid for leak-free cleanroom ceilings. Fluid-gel channel mates with a knife-edge grid for a leak-free seal without gasket bypass — for pharmaceutical and aseptic ceilings. Key Benefits- Leak-free gel seal
- No gasket bypass
- Individually EN 1822 tested
- 73 / 80 mm
ATEX HEPA / ULPA Panel (E10–U15) Generic name for page copy & search — model above is title / SKU ATEX 2014/34/EU mini-pleat HEPA / ULPA panel (EN 1822 E10–U15) in anodised aluminium for explosive zones 1, 2, 21 and 22, with earthing lugs. Ex-proof mini-pleat absolute panel with microglass media, painted-aluminium protection grids and extruded anodised-aluminium frame, individually tested to EN 1822. ATEX 2014/34/EU compliant for zones 1, 2, 21, 22; HFN line meets VDI 6022. Key Benefits- ATEX 2014/34/EU compliant
- Individually EN 1822 tested
- VDI 6022 compliant
- Earthing lugs
Mini-Pleat HEPA / ULPA Panel (90 / 150 mm) Generic name for page copy & search — model above is title / SKU HFP mini-pleat HEPA / ULPA panel in 90 or 150 mm aluminium profile, individually EN 1822-tested E10–U15 (gasket-seal version of the HFP gel-seal range). Aluminium-profile HFP absolute panel in 90 or 150 mm depth with gasket sealing, individually tested to EN 1822 — the conventional-seal alternative to the HFP gel-seal series for cleanroom ceilings and housings. Key Benefits- Individually EN 1822 tested
- 90 / 150 mm depths
- Gasket-seal aluminium profile
Application Pharmaceutical & aseptic ceilings; High-airflow cleanrooms Classification (EN 1822) E10 – U15 Filter Frame Aluminium / MDF with fluid gel Media Microglass Fibre Max. Operating Temperature (°C) up to 80 °C Max. Final Pressure Drop 600 Pa Max. Airflow 1.25 × nominal flow (size dependent) Dimension Standard Standard modular front sizes — EN 15805 (e.g. 287 / 490 / 592 / 610 mm) Installation Options Front- and side-access housings and holding frames available Depth 88 / 104 mm
Mini-Pleat HEPA / ULPA Panel (55 mm) Generic name for page copy & search — model above is title / SKU 55 mm mini-pleat HEPA / ULPA panel, individually EN 1822-tested from E10 to U15. 55 mm aluminium-framed mini-pleat absolute panel for cleanroom terminal and duct filtration. Key Benefits- Individually EN 1822 tested
- 55 mm frame
- Low pressure drop
- Test certificate supplied
Mini-Pleat HEPA / ULPA Panel (110 / 150 mm) Generic name for page copy & search — model above is title / SKU Deep 110/150 mm mini-pleat HEPA / ULPA panel, individually EN 1822-tested E10–U15, in aluminium or MDF frame for higher-airflow absolute filtration. Deeper HFS mini-pleat absolute panel (110 or 150 mm) with microglass media and hotmelt separators, for cleanroom terminals and duct stages that need more media area and airflow than slim panels. Key Benefits- Individually EN 1822 tested
- 110 / 150 mm depths
- Aluminium or MDF frame
- Higher airflow per panel
HEPA / ULPA Box Filter (292 mm, Metal) Generic name for page copy & search — model above is title / SKU Metal-framed deep V-pleat box HEPA / ULPA filter (292 mm), EN 1822-tested E10–U15. 292 mm box variant with sheet-metal frame for robust high-volume absolute filtration in cleanroom AHUs. Key Benefits- Robust metal frame
- High airflow
- Individually EN 1822 tested
- 292 mm
In-duct UV-C light system for sterilizing airborne pathogens and improving indoor air quality.Category Specification Type UV‑C 254 nm lamp (ozone‑free) Lamp Life 9,000–12,000 hours Coverage Up to 3,000–5,000 sq ft HVAC systems Power 120/240V, 20–50W Installation Duct‑mounted Kill Rate 99%+ pathogens (viruses, bacteria, mold) Features UV intensity sensor, safety switch Available Sizes 16–36 inch UV‑C lamps for various duct sizes Advanced Bio-Containment Bag-In-Bag-Out (BIBO) System The Standard in Secure Laboratory Exhaust Management The Nasmora Integrita S3 is a high-performance Bag-In-Bag-Out (BIBO) filtration housing engineered specifically for BSL-3 (Biosafety Level 3) applications and high-containment pharmaceutical facilities. Designed to bridge the gap between standard industrial filtration and extreme containment, the S3 model ensures that maintenance personnel are never exposed to hazardous particulates during filter change-outs.
Category Specification Filter Type V Bank Efficiency ULPA 13 Media Type Synthetic Frame Material SS 304 / SS 316 Seal Type Neoprene Initial Pressure Drop 50 Pa Final Pressure Drop 250 Pa Operating Temperature & Humidity 100°C Standard Sizes 24 × 24 × 12 Title
Go to Top













