Shop

  • Indoor Air Quality Monitor Generic name for page copy & search — model above is title / SKU Desktop indoor air-quality monitor measuring PM2.5, VOC, eCO₂, humidity and temperature with a six-colour status indicator from Good to Hazardous. Mia Air IQ tracks the air you breathe indoors: PM2.5 (0–500 ppb), VOC and eCO₂ (0–60,000 ppb), relative humidity and temperature, displayed with an intuitive colour scale — green (good) through dark blue (hazardous). Key Benefits
    • 5 · VOC · eCO₂ · RH · temp
    • Six-colour status indicator
    • Desktop, compact
  • ULPA Air Purifier Tower (300 m²) Generic name for page copy & search — model above is title / SKU High-capacity purifier tower with ULPA U15 filtration (99.9995%), 27 m² filter area, 2.5 kg granular carbon and up to 72 W UVC — covering large areas up to 300 m². The Tower brings cleanroom-grade ULPA U15 filtration to large open spaces: 27 m² of media, G4 pre-filter, 2.5 kg granular activated carbon, 16 W UVC standard (72 W optional), full sensing and app control in an antistatic aluminium body. Key Benefits
    • ULPA U15 — 99.9995%
    • 300 m² coverage · 27 m² media
    • 5 kg granular carbon
    • UVC up to 72 W
  • Air-Purifying Floor Lamp (50 m²) Generic name for page copy & search — model above is title / SKU Design floor lamp that purifies with HEPA H14 (99.995%) and 500 g activated carbon while lighting the room — sensors, Wi-Fi and wood-finish options, for areas up to 50 m². Two functions in one: ambient lighting and HEPA H14 purification with G4 pre-filter and 500 g carbon stage, full sensor set and app control. Antistatic powder-coated aluminium body with light-oak or walnut finishes. Key Benefits
    • Lighting + purification in one
    • HEPA H14 · 500 g carbon
    • Wood / aluminium design finishes
  • Compact HEPA Air Purifier (25 m²) Generic name for page copy & search — model above is title / SKU Lightweight 7 kg CE-certified purifier with HEPA H10 standard (H13 optional) plus activated carbon, covering rooms up to 25 m². Portable purifier with pre-filter, activated carbon and HEPA H10 (95%) as standard or HEPA H13 (99.99%) optional, in an impact-resistant ABS body. Simple manual control, easy to carry between rooms. Key Benefits
    • 7 kg — easy to move
    • HEPA H13 option (99.99%)
    • Activated carbon stage
  • HEPA Air Purifier (100 m²) Generic name for page copy & search — model above is title / SKU HEPA H14 (99.995%) air purifier with ANTIMIC®-coated filter, activated carbon, 8 W UVC and full air-quality sensing for rooms up to 100 m² — CE, ECARF and Energy Star certified. Flagship purifier: pre-filter, ANTIMIC®-coated HEPA H14 and activated-carbon stages with UVC light, PM1/PM2.5/PM10, CO₂, VOC, humidity and temperature sensors, Wi-Fi app control, five modes and hidden casters. Fireproof impact-resistant ABS body; 2-year warranty. Key Benefits
    • Traps ≥99.99% of pollutants
    • ANTIMIC® HEPA · UVC 8 W
    • Full air-quality sensor set
    • App control · 5 modes
  • Compact Inertial Filter — Self-Cleaning Sand Separator Generic name for page copy & search — model above is title / SKU Compact, self-cleaning inertial sand separator in all-steel modular construction — up to 88–94% separation efficiency with no replaceable media, at roughly half the size of market-average inertial filters. The FC-INF-DF separates dust and sand by multiple-phase flow dynamics, bleeding the separated dust out through a small bleed fan (10–15% of air, by efficiency mode). All-steel, modular and maintenance-free for long-term service, with removable filtering panels for easy cleaning; mountable horizontally or vertically. Third-party lab-tested among the best inertial filters on the market. Key Benefits
    • Self-cleaning — no replaceable media
    • Half the size of market average
    • Efficiency up to A2 88% / A4 94%
    • Removable panels, horizontal or vertical mounting
  • Down Flow Weighing / Dispensing Booth Generic name for page copy & search — model above is title / SKU Turnkey down-flow weighing booth (Class 100 / ISO 5 / GMP A) in AISI 304/316 with multi-stage filtration up to H14/U15, PLC automation and 0.45 m/s laminar down-flow per EU GMP Annex 1. NTK booths protect raw materials during weighing and mixing with laminar down-flow at 0.45 m/s ±20%. Multi-stage filtration (G4/M5 → F7–F9 → E10–H13 → H14/U15 main and exhaust), neutral / negative / positive pressurisation modes, and full PLC monitoring. Delivered turnkey with design, commissioning, DOP tests and validation; ATEX-certificated and BIBO options available. Key Benefits
    • Class 100 / ISO 5 / GMP A
    • PLC control & alarm system
    • AISI 304/316 construction
    • Turnkey with validation & DOP tests
  • Mobile Laminar Air Flow Unit Generic name for page copy & search — model above is title / SKU Mobile laminar air flow unit that keeps finished products inside a laminar clean zone while they move through the facility — docking with static LAF conveyors without contact outside the zone. M-LAF units solve in-plant transport: products transfer from the static LAF conveyor into the mobile laminar zone and can be moved anywhere in the facility without contamination risk, avoiding the cost of multiple fixed cabinets. Key Benefits
    • Laminar protection while moving
    • Docks with static LAF conveyors
    • Avoids multiple fixed cabinets
  • Laminar Air Flow Cabinet (ISO 14644-1) Generic name for page copy & search — model above is title / SKU Vertical laminar air flow cabinet to ISO 14644-1 with G4 pre-filter, HEPA main stage and anti-static curtain isolation — a positive-pressure sterile zone over the product. The LAF cabinet delivers vertical laminar flow through a G4 pre-filter and HEPA stage, with plastic-curtain isolation and positive pressure keeping contaminated air out of the work zone. HEPA change-out at 450 Pa with DOP leak-test fittings provided. Key Benefits
    • ISO 14644-1 laminar flow
    • Positive-pressure curtain isolation
    • DOP leak-test fittings
    • G4 + HEPA two-stage
  • HEPA Terminal Housing (Ceiling Diffuser) Generic name for page copy & search — model above is title / SKU Ceiling terminal housing for HEPA panel filters, in standard (STC) or low-profile (LTC) top-collar and side-collar versions, with swirl, 4-direction or perforated diffusers and Ø150–250 mm collars. H-BOX terminal housings hold HEPA panels (305×305 up to 610×610 mm, depths 70–110 mm) in cleanroom ceilings. Variants: STC standard top collar, LTC low top collar (70/78 mm filters), plus side-collar versions; diffuser faces in swirl (DSW), 4-direction (D4D) or perforated (DP). Key Benefits
    • Standard & low-profile heights
    • Top or side collar entry
    • Swirl / 4-direction / perforated diffusers
    • Fits 305–610 mm HEPA panels
  • Fan Filter Unit — Two-Stage (G4/M5 + HEPA) Generic name for page copy & search — model above is title / SKU Self-powered fan filter unit with two-stage filtration — G4/M5 pre-filter plus HEPA — delivering ISO 14644 laminar flow from 610×610, 610×915 or 610×1220 mm ceiling modules. Push-pull fan filter unit drawing room air through a G4 or M5 coarse pre-filter and discharging through a HEPA stage for the highest outlet purity. Aluminium-alloy / stainless 430 or 304 construction, 220 V 50 Hz, with normal and standby speed modes; standard or custom sizes. Key Benefits
    • Two-stage: G4/M5 + HEPA
    • Laminar flow per ISO 14644 (≈0.45 m/s)
    • Normal / standby speed modes
    • Standard & custom sizes
  • ATEX HEPA / ULPA Panel (E10–U15) Generic name for page copy & search — model above is title / SKU ATEX 2014/34/EU mini-pleat HEPA / ULPA panel (EN 1822 E10–U15) in anodised aluminium for explosive zones 1, 2, 21 and 22, with earthing lugs. Ex-proof mini-pleat absolute panel with microglass media, painted-aluminium protection grids and extruded anodised-aluminium frame, individually tested to EN 1822. ATEX 2014/34/EU compliant for zones 1, 2, 21, 22; HFN line meets VDI 6022. Key Benefits
    • ATEX 2014/34/EU compliant
    • Individually EN 1822 tested
    • VDI 6022 compliant
    • Earthing lugs
  • ATEX Mini-Pleat V-Bank Filter (M6–F9) Generic name for page copy & search — model above is title / SKU ATEX 2014/34/EU mini-pleat V-bank filter (EN 779 M6–F9 / ISO ePM10–ePM1) for explosive zones 1, 2, 21 and 22 — compact, energy-saving and VDI 6022 compliant. Ex-proof mini-pleat V-bank filter with microglass media and hotmelt separators, ATEX 2014/34/EU compliant for zones 1, 2, 21, 22. Compact, high-surface-area design; the MV line fully meets VDI 6022 hygiene requirements. Key Benefits
    • ATEX 2014/34/EU compliant
    • Compact, high surface area
    • Energy saver
    • VDI 6022 compliant
  • ATEX Box Filter (M6–F9) Generic name for page copy & search — model above is title / SKU ATEX 2014/34/EU microglass box filter (EN 779 M6–F9 / ISO ePM10–ePM1) with aluminium separators for explosive zones 1, 2, 21 and 22. Ex-proof deep-pleat box filter with microglass media, aluminium separators and galvanised, aluminium or stainless frame. ATEX 2014/34/EU compliant for zones 1, 2, 21, 22; protection grids both sides and earthing lugs. Key Benefits
    • ATEX 2014/34/EU compliant
    • High efficiency
    • High surface area
    • Protection grids both sides
  • ATEX Pocket / Bag Filter (M5–F8) Generic name for page copy & search — model above is title / SKU ATEX 2014/34/EU glass-fibre pocket filter (EN 779 M5–F8 / ISO ePM10–ePM1) for explosive zones 1, 2, 21 and 22, with earthing lugs and colour-coded media. Ex-proof glass-fibre pocket / bag filter with galvanised frame and sewn fibre assembly, colour-coded by grade (M5 white, M6 green, F7 pink, F8 yellow). ATEX 2014/34/EU compliant for zones 1, 2, 21, 22; supplied with earthing lugs. Key Benefits
    • ATEX 2014/34/EU compliant
    • Low initial pressure drop
    • Low energy use
    • Colour-coded media
  • ATEX Pleated Panel Pre-Filter Generic name for page copy & search — model above is title / SKU ATEX 2014/34/EU pleated panel pre-filter (EN 779 G4 / ISO Coarse) for explosive zones 1, 2, 21 and 22, marked II 2 G Ex h IIC Gb, with integrated earthing lugs. Ex-proof pleated panel pre-filter with synthetic media and galvanised, stainless or aluminium frame, compliant with ATEX Directive 2014/34/EU for gas and dust zones 1, 2, 21 and 22. Supplied with integrated earthing cable lugs. Key Benefits
    • ATEX 2014/34/EU compliant
    • Zones 1, 2, 21, 22
    • Integrated earthing lugs
    • Light, rigid, low ΔP
  • Mini-Pleat HEPA / ULPA Panel (90 / 150 mm) Generic name for page copy & search — model above is title / SKU HFP mini-pleat HEPA / ULPA panel in 90 or 150 mm aluminium profile, individually EN 1822-tested E10–U15 (gasket-seal version of the HFP gel-seal range). Aluminium-profile HFP absolute panel in 90 or 150 mm depth with gasket sealing, individually tested to EN 1822 — the conventional-seal alternative to the HFP gel-seal series for cleanroom ceilings and housings. Key Benefits
    • Individually EN 1822 tested
    • 90 / 150 mm depths
    • Gasket-seal aluminium profile
  • Mini-Pleat HEPA / ULPA Panel (110 / 150 mm) Generic name for page copy & search — model above is title / SKU Deep 110/150 mm mini-pleat HEPA / ULPA panel, individually EN 1822-tested E10–U15, in aluminium or MDF frame for higher-airflow absolute filtration. Deeper HFS mini-pleat absolute panel (110 or 150 mm) with microglass media and hotmelt separators, for cleanroom terminals and duct stages that need more media area and airflow than slim panels. Key Benefits
    • Individually EN 1822 tested
    • 110 / 150 mm depths
    • Aluminium or MDF frame
    • Higher airflow per panel
  • HEPA Terminal Ceiling Module (Micro Hood) Generic name for page copy & search — model above is title / SKU HEPA / ULPA terminal ceiling module (E10–U15) with integral duct collar and adjustable airflow for cleanroom ceilings. Combines a mini-pleat HEPA / ULPA filter with a 150–400 mm duct collar and adjustable airflow for direct cleanroom ceiling and laminar-cabin installation. Key Benefits
    • Integral duct collar
    • Adjustable airflow option
    • Individually EN 1822 tested
    Ready-to-install
  • HEPA / ULPA Box Filter (Plastic Frame) Generic name for page copy & search — model above is title / SKU Plastic / metal-framed V-pleat box HEPA / ULPA filter (E10–U15) for high-airflow cleanroom stages. 592×592×292 box with plastic or metal frame for high airflow at low resistance where a lightweight frame is preferred. Key Benefits
    • Lightweight frame option
    • High airflow
    • Individually EN 1822 tested
    • 292 mm
  •   HEPA / ULPA Box Filter (292 mm, Metal) Generic name for page copy & search — model above is title / SKU Metal-framed deep V-pleat box HEPA / ULPA filter (292 mm), EN 1822-tested E10–U15. 292 mm box variant with sheet-metal frame for robust high-volume absolute filtration in cleanroom AHUs. Key Benefits
    • Robust metal frame
    • High airflow
    • Individually EN 1822 tested
    • 292 mm
     
  • HEPA / ULPA Box Filter (292 mm) Generic name for page copy & search — model above is title / SKU Deep V-pleat box HEPA / ULPA filter (292 mm), individually EN 1822-tested E10–U15, for cleanroom AHUs. 292 mm V-pleat microglass box in MDF / metal frame for high airflow at low resistance in cleanroom air-handling units. Key Benefits
    • High airflow, low ΔP
    • Deep V-pleat pack
    • Individually EN 1822 tested
    • 292 mm
  • Application Pharmaceutical & aseptic ceilings; High-airflow cleanrooms
    Classification (EN 1822) E10 – U15
    Filter Frame Aluminium / MDF with fluid gel
    Media Microglass Fibre
    Max. Operating Temperature (°C) up to 80 °C
    Max. Final Pressure Drop 600 Pa
    Max. Airflow 1.25 × nominal flow (size dependent)
    Dimension Standard Standard modular front sizes — EN 15805 (e.g. 287 / 490 / 592 / 610 mm)
    Installation Options Front- and side-access housings and holding frames available
    Depth 88 / 104 mm
       
  • Gel-Seal HEPA / ULPA Panel (73 / 80 mm) Generic name for page copy & search — model above is title / SKU Gel-seal HEPA / ULPA panel (73 / 80 mm) that seals into a knife-edge grid for leak-free cleanroom ceilings. Fluid-gel channel mates with a knife-edge grid for a leak-free seal without gasket bypass — for pharmaceutical and aseptic ceilings. Key Benefits
    • Leak-free gel seal
    • No gasket bypass
    • Individually EN 1822 tested
    • 73 / 80 mm
Go to Top