| Category | Specification |
|---|---|
| Efficiency | 99.9995% @ 0.12 μm (EN 1822) |
| Media | Glass fiber |
| Frame Material | Anodized aluminum |
| Available Sizes | 610 × 610 × 69 mm / 610 × 610 × 150 mm |
| Initial Pressure Drop | 250–450 Pa |
| Air Flow Capacity | 500–1500 m³/h |
| Temperature Limit | 70°C |
| Cleanroom Class Compatibility | ISO Class 1–3 |
-
Ultra-low penetration air (ULPA) filter for the most demanding cleanroom applications, capturing 99.9995% of particles at 0.12 microns.
-
Four-way square ceiling diffuser designed for efficient air distribution and aesthetic integration into suspended ceilings.
Category Specification Media Granular activated carbon or impregnated non-woven Filter Class Typically G4 + carbon layer Adsorption Capability VOCs, odors, gases (e.g., SO₂, NO₂) Initial Pressure Drop 50–150 Pa Frame Galvanized steel or aluminum Temperature Limit Max 40–60°C Available Sizes Standard panels (e.g., 595×595×46 mm / 595×595×96 mm) Application Airflow 500–2500 m³/h depending on size -
Variable Air Volume (VAV) terminal unit for precise temperature control and energy efficiency in zoned HVAC systems.
Category Specification Product Single Duct VAV Terminal Unit Description Variable Air Volume (VAV) terminal unit for precise temperature control and energy efficiency in zoned HVAC systems. Applications Commercial offices, hotels, educational institutions Air Distribution Type Single Duct VAV Function Modulates airflow to maintain zone temperature and reduce energy consumption Control Compatible with BMS, thermostats, and pressure-independent controls Construction Insulated casing with low‑leakage damper Airflow Range Varies by model (typically 200–2000 m³/h) Pressure Drop Low-pressure design for energy efficiency Power 24V actuator (optional EC motorized damper) Mounting Ceiling or duct-mounted Features Quiet operation, precise airflow control, optional reheat coil -
Sturdy return air grille with an integrated filter frame for easy maintenance and improved indoor air quality.
Category Specification Material Steel / Aluminum, powder‑coated Available Sizes Standard 300×300 mm to 600×600 mm Filter Type 25 mm thick G4 / F5 filter Mounting Ceiling or wall installation Features Removable grille, adjustable louvers Airflow Capacity Up to 1000 m³/h Finish White RAL 9010 -
Photoelectric smoke detector designed for installation in HVAC ducts to detect smoke and prevent its circulation.
Category Specification Type Photoelectric, 24V DC Sensitivity 0.5–4% obs/m Compatible Duct Velocity 0.3–1.5 m/s Output Alarm relay (2A) Features Sampling tube, test port Temperature Range -20 to 60°C Certifications UL 268A, CE Mounting Duct-mounted -
Down Flow Weighing / Dispensing Booth Generic name for page copy & search — model above is title / SKU Turnkey down-flow weighing booth (Class 100 / ISO 5 / GMP A) in AISI 304/316 with multi-stage filtration up to H14/U15, PLC automation and 0.45 m/s laminar down-flow per EU GMP Annex 1. NTK booths protect raw materials during weighing and mixing with laminar down-flow at 0.45 m/s ±20%. Multi-stage filtration (G4/M5 → F7–F9 → E10–H13 → H14/U15 main and exhaust), neutral / negative / positive pressurisation modes, and full PLC monitoring. Delivered turnkey with design, commissioning, DOP tests and validation; ATEX-certificated and BIBO options available. Key Benefits
- Class 100 / ISO 5 / GMP A
- PLC control & alarm system
- AISI 304/316 construction
- Turnkey with validation & DOP tests
-
W-Bank Fine Filter (Economical) Generic name for page copy & search — model above is title / SKU Economical W-bank mini-pleat fine filter (EN 779 M6–F8 / ISO ePM10–ePM1) for value-driven HVAC filtration. MW uses a W-form pack for good media area at an economical price point for general HVAC. Key Benefits
- Economical
- Good media area
- Low resistance
- Incinerable
-
V-Bank Fine Filter (A+ Energy) Generic name for page copy & search — model above is title / SKU Energy-optimised mini-pleat V-bank fine filter reaching Eurovent A+ (EN 779 F7–F9 / ISO ePM1). MVX maximises media area and minimises resistance for Eurovent A+ energy performance in HVAC and gas-turbine final filtration. Key Benefits
- Eurovent A+ energy
- Lowest pressure drop
- High media area
- Long life
-
High-Temperature HEPA Box Filter (250 °C) Generic name for page copy & search — model above is title / SKU Microglass box filter spanning F7 fine up to H14 HEPA (EN 1822), rated to 250 °C for high-temperature clean air. High-temperature box with microglass separators and stainless / galvanised frame, silicone-sealed and rated to 250 °C — fine to absolute in one range. Key Benefits
- 250 °C rated
- Fine to HEPA H14
- Robust metal construction
- Silicone-sealed
-
HEPA / ULPA Box Filter (Plastic Frame) Generic name for page copy & search — model above is title / SKU Plastic / metal-framed V-pleat box HEPA / ULPA filter (E10–U15) for high-airflow cleanroom stages. 592×592×292 box with plastic or metal frame for high airflow at low resistance where a lightweight frame is preferred. Key Benefits
- Lightweight frame option
- High airflow
- Individually EN 1822 tested
- 292 mm
-
Energy-Efficient V-Bank Fine Filter Generic name for page copy & search — model above is title / SKU Energy-efficient mini-pleat V-bank fine filter (EN 779 F7–F9 / ISO ePM1) balancing efficiency and fan energy. MVEE offers a strong efficiency-to-energy balance for everyday HVAC final filtration. Key Benefits
- Energy efficient
- High media area
- Stable efficiency
- Incinerable
-
High-Temperature V-Bank Filter (350 °C) Generic name for page copy & search — model above is title / SKU Silicone-free microglass V-bank filter (EN 779 M6–F8 / ISO ePM1) rated to 350 °C for painting / curing ovens. High-capacity microglass V-bank with metal separators and an extruded aluminium / steel frame, rated to 350 °C and silicone-free. Key Benefits
- 350 °C rated
- Silicone-free
- High surface area
- Energy saver
-
High-Temperature V-Bank Fine Filter (120 °C) Generic name for page copy & search — model above is title / SKU Plastic V-bank fine filter (EN 779 F7–F9 / ISO ePM1) rated to 120 °C for warm-air HVAC and process duty. Polyamide-framed V-bank fine filter rated to 120 °C for elevated-temperature ventilation while retaining low resistance. Key Benefits
- 120 °C rated
- High airflow
- Low pressure drop
- High media area
-
V-Form Coalescer / Pre-Filter Generic name for page copy & search — model above is title / SKU Compact V-form synthetic coalescer / pre-filter (EN 779 G4 / ISO Coarse) for gas-turbine air-intake systems. V-form synthetic pack with a reverse-flow option (MVX-G) packing high media area into a short depth for gas-turbine coalescing and pre-filtration. Key Benefits
- Compact V-form
- Reverse-flow option
- High media area
- Low resistance
-
Carbon + F7 Combination V-Bank Generic name for page copy & search — model above is title / SKU Combination V-bank delivering ISO ePM1 (F7) particulate efficiency plus activated-carbon gas / odour removal in a single filter. Combines an F7 microglass particulate stage with an activated-carbon layer for simultaneous PM1 and gas / odour control. Key Benefits
- F7 particulate + carbon
- One-stage solution
- High airflow
- Space-saving
-
ATEX Mini-Pleat V-Bank Filter (M6–F9) Generic name for page copy & search — model above is title / SKU ATEX 2014/34/EU mini-pleat V-bank filter (EN 779 M6–F9 / ISO ePM10–ePM1) for explosive zones 1, 2, 21 and 22 — compact, energy-saving and VDI 6022 compliant. Ex-proof mini-pleat V-bank filter with microglass media and hotmelt separators, ATEX 2014/34/EU compliant for zones 1, 2, 21, 22. Compact, high-surface-area design; the MV line fully meets VDI 6022 hygiene requirements. Key Benefits
- ATEX 2014/34/EU compliant
- Compact, high surface area
- Energy saver
- VDI 6022 compliant
-
Acid-Gas Activated-Carbon V-Bank Generic name for page copy & search — model above is title / SKU Impregnated-carbon combination V-bank targeting SO₂, acids, ammonia and VOCs alongside particulate. MV-ACX uses impregnated activated carbon to target acidic gases (SO₂), ammonia and VOCs in one high-airflow V-bank stage. Key Benefits
- Targets SO₂, acids, NH₃, VOC
- High airflow
- Low resistance
- Combination filtration
-
Activated-Carbon Combination V-Bank Generic name for page copy & search — model above is title / SKU Combination V-bank carrying activated carbon between synthetic layers for simultaneous gas / odour and particulate control at high airflow. Activated carbon between synthetic media in a V-bank for one-stage molecular + particulate capture in HVAC, museums and airports. Key Benefits
- Gas + particulate in one stage
- High airflow
- Low resistance
- High carbon area
-
Activated-Carbon V-Cell Filter Generic name for page copy & search — model above is title / SKU Deep V-cell granular-activated-carbon filter holding 12–20 kg carbon for extended gas / odour adsorption. V-cell configuration maximising carbon mass (12–20 kg) for long-life gas and odour adsorption in HVAC and exhaust. Key Benefits
- High carbon charge
- Long life
- V-cell high capacity
- Refillable
-
Terminal Single-Cell V Filter Generic name for page copy & search — model above is title / SKU Slim single-cell V terminal filter (F8 up to H13) for terminal filtration in air-treatment units. Compact single-cell V spanning F8–F9 fine to E11–H13 absolute in one slim footprint, for terminal housings and air-treatment units. Key Benefits
- High airflow
- Low pressure drop
- Compact single-cell
- Wide class range
-
Mini-Pleat V-Bank Fine Filter Generic name for page copy & search — model above is title / SKU Mini-pleat V-bank fine filter (EN 779 M6–F9 / ISO ePM10–ePM1) delivering high airflow at low resistance. V-bank header-frame filter folding a large microglass area into a compact cell for high airflow, low pressure drop and strong energy performance. Key Benefits
- High airflow, low resistance
- Very high media area
- Energy saver
- Incinerable
-
Advanced indoor air quality sensor monitoring CO2, VOCs, temperature, and humidity for optimal environmental control.
Category Specification Parameters Measured CO₂ (0–5000 ppm), VOCs (index), Temperature (0–50°C), Humidity (0–100% RH) Accuracy CO₂ ±50 ppm, Temperature ±0.5°C, Humidity ±3% RH Output Options Analog (0–10V / 4–20mA), Digital (Modbus, BACnet) Power Supply 12–24V DC Response Time <60 seconds Mounting Type Wall or duct mounting Certifications CE, RoHS -
Water-Repellent Rigid Pleated Pre-Filter Generic name for page copy & search — model above is title / SKU Water-repellent rigid pleated pre-filter (EN 779 G4 / ISO Coarse) for high-humidity, coastal and gas-turbine intake conditions. MSKPN with water-repellent media that maintains dust-holding in high-humidity and gas-turbine intake air where standard media would wet out. Key Benefits
- Water-repellent media
- Rigid frame
- Leak-free seal
- Stable in humid air
-
Rigid-Frame Pleated Pre-Filter Generic name for page copy & search — model above is title / SKU Light rigid pleated pre-filter (EN 779 G4 / ISO Coarse) with ABS, galvanised or stainless frame and a leakage-free polyurethane seal. Rigid-frame pleated panel with polyurethane sealant for a leak-free seal; ABS, galvanised or stainless frame options for HVAC and industrial primary filtration. Key Benefits
- Light & rigid
- Leakage-free seal
- Tidy pleat spacing
- Frame options