- High dust-holding capacity
- Depth-loading media
- Cut-to-size / custom dimensions
- Low initial pressure drop
-
Synthetic Filter Media Roll (Coarse) Generic name for page copy & search — model above is title / SKU Synthetic progressive-density media on rolls for automatic roll-filter units and cut-to-size pre-filtration, rated ISO Coarse to ISO ePM10. Continuous depth-loading synthetic media supplied on rolls (grades PF, PB) for roll-filter banks, AHU intakes and custom panel fabrication — high dust-holding at low resistance. Key Benefits
-
Heating, Ventilation, and Air Conditioning (HVAC) systems are the backbone of healthy indoor environments. When equipped with the right filtration technology, they significantly improve Indoor Air Quality (IAQ) by removing airborne particles, harmful gases, chemical vapors, and unpleasant odors. High‑performance filters also reduce system load, lower energy consumption, and help decrease carbon emissions — making air purification both effective and sustainable. With Mikropor’s advanced HVAC filtration solutions, facilities can achieve cleaner, safer, and more efficient airflow. Each filter is engineered for maximum performance, ensuring reliable particle capture, optimized airflow resistance, and long service life. Whether for commercial buildings, industrial plants, healthcare facilities, or cleanroom environments, Mikropor filters support your sustainability goals while delivering superior air quality.
-
Category Specification Filter Class M5 (EN779), ePM10 50–65% Media Synthetic fiber Frame Cardboard or metal Thickness 25–48 mm Initial Pressure Drop 50–80 Pa Final Pressure Drop 120–200 Pa -
Photoelectric smoke detector designed for installation in HVAC ducts to detect smoke and prevent its circulation.
Category Specification Type Photoelectric, 24V DC Sensitivity 0.5–4% obs/m Compatible Duct Velocity 0.3–1.5 m/s Output Alarm relay (2A) Features Sampling tube, test port Temperature Range -20 to 60°C Certifications UL 268A, CE Mounting Duct-mounted -
Variable Air Volume (VAV) terminal unit for precise temperature control and energy efficiency in zoned HVAC systems.
Category Specification Product Single Duct VAV Terminal Unit Description Variable Air Volume (VAV) terminal unit for precise temperature control and energy efficiency in zoned HVAC systems. Applications Commercial offices, hotels, educational institutions Air Distribution Type Single Duct VAV Function Modulates airflow to maintain zone temperature and reduce energy consumption Control Compatible with BMS, thermostats, and pressure-independent controls Construction Insulated casing with low‑leakage damper Airflow Range Varies by model (typically 200–2000 m³/h) Pressure Drop Low-pressure design for energy efficiency Power 24V actuator (optional EC motorized damper) Mounting Ceiling or duct-mounted Features Quiet operation, precise airflow control, optional reheat coil -
Electronic air cleaner using electrostatic precipitation to remove fine particles, smoke, and oil mist.
Category Specification Efficiency 95%+ for 0.01–10 μm particles Ionization Voltage 5–12 kV Collector Cells Washable aluminum plates Airflow Capacity 1000–5000 m³/h per unit Pressure Drop 20–50 Pa Ultra-low penetration air (ULPA) filter for the most demanding cleanroom applications, capturing 99.9995% of particles at 0.12 microns.Category Specification Efficiency 99.9995% @ 0.12 μm (EN 1822) Media Glass fiber Frame Material Anodized aluminum Available Sizes 610 × 610 × 69 mm / 610 × 610 × 150 mm Initial Pressure Drop 250–450 Pa Air Flow Capacity 500–1500 m³/h Temperature Limit 70°C Cleanroom Class Compatibility ISO Class 1–3 Sturdy return air grille with an integrated filter frame for easy maintenance and improved indoor air quality.Category Specification Material Steel / Aluminum, powder‑coated Available Sizes Standard 300×300 mm to 600×600 mm Filter Type 25 mm thick G4 / F5 filter Mounting Ceiling or wall installation Features Removable grille, adjustable louvers Airflow Capacity Up to 1000 m³/h Finish White RAL 9010 High-accuracy differential pressure transmitter for monitoring filter status and airflow in HVAC systems.Category Specification Measurement Range 0–500 Pa (typical for filter monitoring) Accuracy ±1% FS Output Signal 4–20 mA, 0–10 V Power Supply 12–24 V DC Response Time <1 second Features Optional LCD display, IP65 housing Applications Filter status monitoring, airflow measurement Medium efficiency bag filter designed for HVAC systems requiring good dust holding capacity and low pressure drop.Category Specification Unit Size 600 × 600 × 300 mm Filter HEPA / ULPA (99.99% @ 0.3 μm) Airflow 500–900 m³/h Power Consumption 50–150 W Noise Level <55 dB(A) Material Aluminum frame Fan Type EC fan Cleanroom Efficiency ISO Class 5–7 Self-contained fan filter unit providing filtered air for cleanroom applications, typically with a HEPA or ULPA filter.Category Specification Unit Size 600 × 600 × 300 mm Filter HEPA / ULPA (99.99% @ 0.3 μm) Airflow 500–900 m³/h Power Consumption 50–150 W Noise Level <55 dB(A) Material Aluminum frame Fan Type EC fan Cleanroom Efficiency ISO Class 5–7 In-duct UV-C light system for sterilizing airborne pathogens and improving indoor air quality.Category Specification Type UV‑C 254 nm lamp (ozone‑free) Lamp Life 9,000–12,000 hours Coverage Up to 3,000–5,000 sq ft HVAC systems Power 120/240V, 20–50W Installation Duct‑mounted Kill Rate 99%+ pathogens (viruses, bacteria, mold) Features UV intensity sensor, safety switch Available Sizes 16–36 inch UV‑C lamps for various duct sizes Title