| Category | Specification |
|---|---|
| Media | Granular activated carbon or impregnated non-woven |
| Filter Class | Typically G4 + carbon layer |
| Adsorption Capability | VOCs, odors, gases (e.g., SO₂, NO₂) |
| Initial Pressure Drop | 50–150 Pa |
| Frame | Galvanized steel or aluminum |
| Temperature Limit | Max 40–60°C |
| Available Sizes | Standard panels (e.g., 595×595×46 mm / 595×595×96 mm) |
| Application Airflow | 500–2500 m³/h depending on size |
-
Odor control filter utilizing activated carbon media to absorb gaseous contaminants and VOCs.
-
Heating, Ventilation, and Air Conditioning (HVAC) systems are the backbone of healthy indoor environments. When equipped with the right filtration technology, they significantly improve Indoor Air Quality (IAQ) by removing airborne particles, harmful gases, chemical vapors, and unpleasant odors. High‑performance filters also reduce system load, lower energy consumption, and help decrease carbon emissions — making air purification both effective and sustainable. With Mikropor’s advanced HVAC filtration solutions, facilities can achieve cleaner, safer, and more efficient airflow. Each filter is engineered for maximum performance, ensuring reliable particle capture, optimized airflow resistance, and long service life. Whether for commercial buildings, industrial plants, healthcare facilities, or cleanroom environments, Mikropor filters support your sustainability goals while delivering superior air quality.
-
Mikropor coarse air filters serve as the first line of defense in HVAC and industrial ventilation systems. Engineered to capture large dust particles, fibers, lint, and debris, these filters protect downstream equipment and significantly extend the service life of fine, compact, and HEPA filtration stages. Ideal for commercial buildings, factories, warehouses, AHUs, FCUs, and general ventilation systems, Mikropor coarse filters deliver reliable performance with low pressure drop and high dust‑holding capacity — ensuring cleaner air and reduced maintenance costs.
MediaSynthetic
Final Pressure Drop250 Pa
Operating Temperature80°C
Filter Efficiency*G2 – G3 – G4
Filter Class**ISO Coarse * According to EN 779:2012 ** According to ISO 16890 
-
High-accuracy differential pressure transmitter for monitoring filter status and airflow in HVAC systems.
Category Specification Measurement Range 0–500 Pa (typical for filter monitoring) Accuracy ±1% FS Output Signal 4–20 mA, 0–10 V Power Supply 12–24 V DC Response Time <1 second Features Optional LCD display, IP65 housing Applications Filter status monitoring, airflow measurement -
Electronic air cleaner using electrostatic precipitation to remove fine particles, smoke, and oil mist.
Category Specification Efficiency 95%+ for 0.01–10 μm particles Ionization Voltage 5–12 kV Collector Cells Washable aluminum plates Airflow Capacity 1000–5000 m³/h per unit Pressure Drop 20–50 Pa Medium efficiency bag filter designed for HVAC systems requiring good dust holding capacity and low pressure drop.Category Specification Unit Size 600 × 600 × 300 mm Filter HEPA / ULPA (99.99% @ 0.3 μm) Airflow 500–900 m³/h Power Consumption 50–150 W Noise Level <55 dB(A) Material Aluminum frame Fan Type EC fan Cleanroom Efficiency ISO Class 5–7 Fan Filter Unit — Two-Stage (G4/M5 + HEPA) Generic name for page copy & search — model above is title / SKU Self-powered fan filter unit with two-stage filtration — G4/M5 pre-filter plus HEPA — delivering ISO 14644 laminar flow from 610×610, 610×915 or 610×1220 mm ceiling modules. Push-pull fan filter unit drawing room air through a G4 or M5 coarse pre-filter and discharging through a HEPA stage for the highest outlet purity. Aluminium-alloy / stainless 430 or 304 construction, 220 V 50 Hz, with normal and standby speed modes; standard or custom sizes. Key Benefits- Two-stage: G4/M5 + HEPA
- Laminar flow per ISO 14644 (≈0.45 m/s)
- Normal / standby speed modes
- Standard & custom sizes
Self-contained fan filter unit providing filtered air for cleanroom applications, typically with a HEPA or ULPA filter.Category Specification Unit Size 600 × 600 × 300 mm Filter HEPA / ULPA (99.99% @ 0.3 μm) Airflow 500–900 m³/h Power Consumption 50–150 W Noise Level <55 dB(A) Material Aluminum frame Fan Type EC fan Cleanroom Efficiency ISO Class 5–7 Compact Inertial Filter — Self-Cleaning Sand Separator Generic name for page copy & search — model above is title / SKU Compact, self-cleaning inertial sand separator in all-steel modular construction — up to 88–94% separation efficiency with no replaceable media, at roughly half the size of market-average inertial filters. The FC-INF-DF separates dust and sand by multiple-phase flow dynamics, bleeding the separated dust out through a small bleed fan (10–15% of air, by efficiency mode). All-steel, modular and maintenance-free for long-term service, with removable filtering panels for easy cleaning; mountable horizontally or vertically. Third-party lab-tested among the best inertial filters on the market. Key Benefits- Self-cleaning — no replaceable media
- Half the size of market average
- Efficiency up to A2 88% / A4 94%
- Removable panels, horizontal or vertical mounting
High-efficiency pleated pre-filter designed to capture large particles and extend the life of downstream filters.Category Specification Filter Class G4 (EN779:2012), ~90% arrestance Media Synthetic fiber / Polyester Frame Cardboard / Galvanized Steel / ABS Initial Pressure Drop 22–40 Pa Final Pressure Drop ≤200–250 Pa Air Flow 1180–3400 m³/h (varies by size, e.g., 595×595×22 mm at 1700 m³/h) Temperature Limit Max 80°C Common Sizes 595×595×20 / 46 / 96 mm (other sizes available) HEPA Terminal Housing (Ceiling Diffuser) Generic name for page copy & search — model above is title / SKU Ceiling terminal housing for HEPA panel filters, in standard (STC) or low-profile (LTC) top-collar and side-collar versions, with swirl, 4-direction or perforated diffusers and Ø150–250 mm collars. H-BOX terminal housings hold HEPA panels (305×305 up to 610×610 mm, depths 70–110 mm) in cleanroom ceilings. Variants: STC standard top collar, LTC low top collar (70/78 mm filters), plus side-collar versions; diffuser faces in swirl (DSW), 4-direction (D4D) or perforated (DP). Key Benefits- Standard & low-profile heights
- Top or side collar entry
- Swirl / 4-direction / perforated diffusers
- Fits 305–610 mm HEPA panels
Absolute HEPA filter providing high-level filtration for critical environments, capturing 99.95% of particles at 0.3 microns. Key Highlights:- Minipleat design
- lowest static pressure
Category Specification Applications Hospitals, pharmaceutical manufacturing, cleanrooms, laboratories Filter Type Panel Efficiency E10, E11, E12, H13, H14, U15, U16, U17 Media Type Microfine fiberglass Frame Material Anodised Aluminum Seal Type Neoprene Endless, PU Depth Available 69 mm, 70 mm, 80 mm Initial Pressure Drop 50 Pa Final Pressure Drop 600 Pa Operating Temperature & Humidity 80°C Standard Sizes 24×24×12, 24×12×12 Additional Details Individual certificate will be provided Certifications & Compliance EN1822 Title
Go to Top